The
MSDS format adheres to the standards and regulatory requirements
of
the United States and may not meet regulatory requirements
in
other countries.
DuPont
Page 1
Material
Safety Data Sheet
----------------------------------------------------------------------
"KRYTOX"
1500, 1600, 16000 & 16000N Series Fluorinated Vacuum Pump
Fluids/Oils
5357PP
Revised 18-JAN-2001
----------------------------------------------------------------------
----------------------------------------------------------------------
CHEMICAL
PRODUCT/COMPANY IDENTIFICATION
----------------------------------------------------------------------
Material
Identification
"KRYTOX"
is a registered trademark of DuPont.
Corporate
MSDS Number : DU002671
Grade
: See Additional Information and References
Company
Identification
MANUFACTURER/DISTRIBUTOR
DuPont
1007
Market Street
Wilmington,
DE 19898
PHONE
NUMBERS
Product
Information : 1-800-441-7515 (outside the U.S.
302-774-1000)
Transport
Emergency : CHEMTREC 1-800-424-9300(outside U.S.
703-527-3887)
Medical
Emergency : 1-800-441-3637 (outside the U.S.
302-774-1000)
----------------------------------------------------------------------
COMPOSITION/INFORMATION
ON INGREDIENTS
----------------------------------------------------------------------
Components
Material
CAS Number %
Perfluoroalkylether
60164-51-4 100
----------------------------------------------------------------------
HAZARDS
IDENTIFICATION
----------------------------------------------------------------------
#
Potential Health Effects
Skin
contact may cause reddening of the skin. The product
was
not a skin irritant or skin sensitizer in a 100 person
human
patch test.
Based
on data from animal tests, eye contact may cause eye
irritation
with discomfort, tearing or blurring of vision.
Inhalation
of fluorine containing compounds released as
decomposition
products from overheated or burning product
may
cause lung irritation and pulmonary edema which require
medical
treatment.
5357PP
DuPont Page 2
Material
Safety Data Sheet
(HAZARDS
IDENTIFICATION - Continued)
Carcinogenicity
Information
None
of the components present in this material at concentrations
equal
to or greater than 0.1% are listed by IARC, NTP, OSHA or ACGIH
as
a carcinogen.
----------------------------------------------------------------------
FIRST
AID MEASURES
----------------------------------------------------------------------
#
First Aid
INHALATION
If
inhaled, remove to fresh air. If not breathing, give
artificial
respiration. If breathing is difficult, give oxygen.
Call
a physician.
SKIN
CONTACT
The
compound is not likely to be hazardous by skin contact but
cleansing
the skin after use is advisable.
EYE
CONTACT
In
case of contact, immediately flush eyes with plenty of water
for
at least 15 minutes. Call a physician.
INGESTION
If
swallowed, do not induce vomiting. Immediately give 2 glasses
of
water. Never give anything by mouth to an unconscious person.
Call
a physician.
Notes
to Physicians
Activated
charcoal mixture may be administered. To prepare
activated
charcoal mixture, suspend 50 grams activated charcoal in
400
mL water and mix thoroughly. Administer 5 mL/kg, or 350 mL
for
an average adult.
----------------------------------------------------------------------
FIRE
FIGHTING MEASURES
----------------------------------------------------------------------
Flammable
Properties
Flash
Point : Does not ignite
Method
: PMCC
Non-combustible.
Extinguishing
Media
As
appropriate for combustibles in area.
5357PP
DuPont Page 3
Material
Safety Data Sheet
(FIRE
FIGHTING MEASURES - Continued)
Fire
Fighting Instructions
Wear
self-contained breathing apparatus. Wear full protective
equipment.
Decomposition
at flame temperatures may form toxic fluorine
compounds.
Avoid breathing decomposition products.
----------------------------------------------------------------------
ACCIDENTAL
RELEASE MEASURES
----------------------------------------------------------------------
Safeguards
(Personnel)
NOTE:
Review FIRE FIGHTING MEASURES and HANDLING (PERSONNEL)
sections
before proceeding with clean-up. Use appropriate
PERSONAL
PROTECTIVE EQUIPMENT during clean-up.
Spill
Clean Up
Soak
up with sawdust, sand, oil dry or other absorbent material.
Shovel
or sweep up.
Accidental
Release Measures
Place
in container for disposal. Remove source of heat and
flame.
----------------------------------------------------------------------
HANDLING
AND STORAGE
----------------------------------------------------------------------
Handling
(Personnel)
Perfluoropolyether
oils are considered to be inert and of
low
toxicity. However, as with all lubricants it is
important
to observe correct hygiene practices. Avoid
contact
with eyes. Avoid contact with skin. Wash thoroughly
after
handling.
Storage
Keep
container tightly closed. Do not store or consume food,
drink
or tobacco in areas where they may become contaminated with
this
material.
Keep
away from heat and flames to avoid decomposition
products.
5357PP
DuPont Page 4
Material
Safety Data Sheet
----------------------------------------------------------------------
EXPOSURE
CONTROLS/PERSONAL PROTECTION
----------------------------------------------------------------------
Engineering
Controls
Keep
container tightly closed.
Use
ventilation when the oil is heated above 550 degF. Keep
away
from heat and flames.
Personal
Protective Equipment
EYE/FACE
PROTECTION
Wear
safety glasses or coverall chemical splash goggles.
REKSPIRATOR
Wear
NIOSH approved respiratory protection as appropriate.
PROTECTIVE
CLOTHING
Where
there is potential for skin contact have available
and
wear as appropriate, impervious gloves, apron, pants,
and
jacket.
Exposure
Guidelines
Exposure
Limits
"KRYTOX"
1500, 1600, 16000 & 16000N Series Fluorinated Vacuum Pump
Fluids/Oils
PEL
(OSHA) : None Established
TLV
(ACGIH) : None Established
----------------------------------------------------------------------
PHYSICAL
AND CHEMICAL PROPERTIES
----------------------------------------------------------------------
Physical
Data
Solubility
in Water : Negligible WT%
pH
: Neutral
Odor
: Odorless
Form
: Liquid, viscous oil
Color
: Colorless
Specific
Gravity : 1.86-1.91 @ 24 deg C (75 deg F)
Pour
Point : -45 to -5 deg C (-49 to -25 deg F)
5357PP
DuPont Page 5
Material
Safety Data Sheet
----------------------------------------------------------------------
STABILITY
AND REACTIVITY
----------------------------------------------------------------------
Chemical
Stability
Stable.
Incompatibility
with Other Materials
None
reasonably foreseeable.
Decomposition
Heating
above 350 degC (662 degF) may form potentially toxic
fluorine
compounds. Depolymerization may occur in the
presence
of some metal oxides at temperatures above 288 degC
(550
degF). Decomposition occurs at increasing rates as
temperature
is raised above 355 degC (670 degF).
Polymerization
Polymerization
will not occur.
----------------------------------------------------------------------
TOXICOLOGICAL
INFORMATION
----------------------------------------------------------------------
#
Animal Data
Perfluoroalkylether:
Inhalation
4 Hour ALC: >19.54 mg/L in rats
Skin
Absorption ALD: >17,000 mg/kg in rabbits
Oral
ALD: >25,000 mg/kg in rats
The
product is a mild skin and eye irritant, but is not a
skin
sensitizer in tests on animals. A single inhalation
exposure
caused nonspecific effects such as respiratory
irritation.
Exposure to thermal decomposition products
produced
irritation, irregular respiration, tremors and
increased
liver weight. Repeated inhalation exposures to
10,
100, or 1000 mg/m3 caused increased lung weights and
microscopic
particle-laden macrophages in the lungs and
lymph
nodes; this was an expected pulmonary response to high
aerosol
concentrations of an inert material. No animal test
reports
are available to define carcinogenic, developmental,
or
reproductive hazards. Tests have shown that the product
did
not cause genetic damage in bacterial cell cultures.
5357PP
DuPont Page 6
Material
Safety Data Sheet
----------------------------------------------------------------------
DISPOSAL
CONSIDERATIONS
----------------------------------------------------------------------
Waste
Disposal
Treatment,
storage, transportation, and disposal must be in
accordance
with applicable Federal, State/Provincial, and Local
regulations.
Do not flush to surface water or sanitary sewer
system.
----------------------------------------------------------------------
TRANSPORTATION
INFORMATION
----------------------------------------------------------------------
Shipping
Information
Not
Regulated as a hazardous material by DOT, IMO, or IATA.
----------------------------------------------------------------------
REGULATORY
INFORMATION
----------------------------------------------------------------------
U.S.
Federal Regulations
TSCA
Inventory Status : Reported/Included.
TITLE
III HAZARD CLASSIFICATIONS SECTIONS 311, 312
Acute
: Yes
Chronic
: No
Fire
: No
Reactivity
: No
Pressure
: No
----------------------------------------------------------------------
OTHER
INFORMATION
----------------------------------------------------------------------
NFPA,
NPCA-HMIS
NPCA-HMIS
Rating
Health
: 1
Flammability
: 0
Reactivity
: 0
Personal
Protection rating to be supplied by user depending on use
conditions.
Additional
Information
GRADES
1506,
1514, 1525, 1618, 1625, 1645, 16140, 16256, 16350,
16140N
& 16256N
5357PP
DuPont Page 7
Material
Safety Data Sheet
(Continued)
----------------------------------------------------------------------
The
data in this Material Safety Data Sheet relates only to the
specific
material designated herein and does not relate to use in
combination
with any other material or in any process.
Responsibility
for MSDS : MSDS Coordinator
Address
: DuPont Chemical Solutions Enterprise
Wilmington,
DE 19898
Telephone
: 800-441-7515
#
Indicates updated section.
This
information is based upon technical information believed to be
reliable.
It is subject to revision as additional knowledge and
experience
is gained.
End